Boost
Boost

Reactive Power Management & Power Factor Correction

EEC-984

Course Code

5 Days

Duration

5

Upcoming Dates

Download Brochure
Sector Logo

Sector Name

Electrical Engineering

Send by WhatsApp
20 Dec 2026 | 24 Dec 2026
Salalah, Oman
$4,250
Limited Seats
28 Dec 2026 | 01 Jan 2027
Dubai, UAE
$4,250
Upcoming
10 Jan 2027 | 14 Jan 2027
Riyadh, KSA
$4,250
Upcoming
24 May 2027 | 28 May 2027
Geneva, switzerland
$5,950
Upcoming
04 Oct 2027 | 08 Oct 2027
Abu Dhabi, UAE
$4,250
Upcoming

Course Introduction

In an ideal AC power system, the voltage and frequency at every supply point would be constant and free from harmonics, and the power factor would be unity. Most Industrial loads have lagging power factors. That is, they absorb reactive power. The load current, therefore, tends to be larger than is required to supply the real power alone. Only the real power is ultimately useful in energy conversion, and the excess load current represents a waste to the consumer, who has to pay not only for the excess cable capacity to carry it but also for the excess joule loss produced in the supply cables.


The supply utilities also have good reasons for not transmitting unnecessary reactive power from generators to loads. Their generators and distribution networks cannot be used at full efficiency, and the control of voltage in the supply system can become more difficult. Supply tariffs to industrial consumers almost always penalize low power factor loads.
 

Most AC power systems are three-phase and are designed for balanced operation. Unbalanced operation gives rise to components of current in the wrong phase sequence (i.e., negative and zero sequence components). Such components can have undesirable effects, including additional losses in motor and generator units, oscillating torque in AC machines, increased ripple reactive in rectifier, malfunctions of several types of equipment, saturation of transformers, and excessive neutral currents.

 

The load compensation improves the phase balancing and power factor correction of unsymmetrical loads. Many utilities need this particular course, which covers the illustration of the main concepts of reactive power management using actual case studies.

Course Objectives

  • Understanding the main concepts of the management of reactive power
  • How to improve the quality of supply in an AC power system
  • How to use the generators, distribution networks, and equipment at full efficiency
  • To know how to select, calculate, and connect the reactive power compensator to improve the power factor, the voltage regulation, and the load balancing in the utilities and industrial networks.
  • To know the problems that appear due to the use of compensation equipment and how to mitigate those problems
Download Brochure